Lower Carbon Footprint:
Connections in steel structures are critical components that ensure the stability, safety, and performance of steel frameworks. These connections—including bolted, welded, and hybrid joints—enable seamless integration of beams, columns, trusses, and braces while supporting heavy loads and resisting environmental stresses. Liyou specializes in engineered steel connections designed for durability, precision, and adaptability, providing architects and engineers with reliable solutions for industrial, commercial, and residential projects. Our connection systems enhance structural integrity while allowing flexible designs and efficient on-site assembly.
High Load-Bearing Capacity: Designed to maintain stability under heavy and dynamic loads.
Precision Engineering: Manufactured for accurate alignment and secure fit.
Durable & Resistant: Withstands corrosion, environmental wear, and mechanical stress.
Flexible Design Options: Supports various joint types and connection methods.
Easy Installation: Streamlined designs facilitate faster on-site assembly.
Industrial Buildings: Factories, warehouses, and production facilities
Commercial Projects: Office towers, shopping centers, and exhibition halls
Infrastructure: Bridges, transportation hubs, and public buildings
Residential & Mixed-Use: High-rise apartments, villas, and community structures
Availability: | |
---|---|
Quantity: | |
1. Anchor Bolt and Fastener Part
No. | Item | Specification |
1 | Anchor bolt 1 | M20×400 |
2 | Anchor bolt 2 | M16×260 |
3 | High-strength bolt | M20, M16, 8.8S |
4 | Common bolt | M16 |
5 | Galvanized bolt | M12 |
6 | Turnbuckle bolt | M16 |
7 | Sag rod | Ø12 |
2. Main Steel Structure Part
No. | Item | Specification |
1 | Steel column (Q235B) | HN396×200×7×11 |
2 | Wind column (Q235B) | SHS150×100×5.0 |
3 | Roof truss beam (Q235B) | HN396×200×7×11 |
4 | Floor main beam (Q235B) | HN600×200×11×17 |
5 | Tie bar (Q235B) | SHS100×100×5.0 |
6 | Horizontal/Column brace (Q235B) | Ø16 |
7 | Steel stairs | [250#、[200#、[160# channel steel, 4mm checkered plate] |
8 | Angle brace (Q235B) | L50×6.0 |
9 | Roof purlin (Q355B) | C250×75×20×2.0 |
10 | Wall purlin (Q355B) | C250×75×20×2.0 |
11 | Connecting plate (Q235B) | 6mm–16mm |
3. Enclosure Part
No. | Item | Specification |
1 | Roof plate | 0.6mm thick, type 840 steel sheet |
2 | Exterior wall | 0.6mm thick, type 900 steel sheet |
3 | Steel man door | 910×2010×2 |
4 | Stainless steel handrail | 1.1m high |
5 | Roof ventilator | 600×600 |
6 | Gutter | 2.0mm galvanized |
7 | Downpipe | Ø110 PVC |
8 | Trimming | 0.55mm thick steel plate |
9 | Hardware accessories | Nails, supports, structural glue, etc. |
1. Anchor Bolt and Fastener Part
No. | Item | Specification |
1 | Anchor bolt 1 | M20×400 |
2 | Anchor bolt 2 | M16×260 |
3 | High-strength bolt | M20, M16, 8.8S |
4 | Common bolt | M16 |
5 | Galvanized bolt | M12 |
6 | Turnbuckle bolt | M16 |
7 | Sag rod | Ø12 |
2. Main Steel Structure Part
No. | Item | Specification |
1 | Steel column (Q235B) | HN396×200×7×11 |
2 | Wind column (Q235B) | SHS150×100×5.0 |
3 | Roof truss beam (Q235B) | HN396×200×7×11 |
4 | Floor main beam (Q235B) | HN600×200×11×17 |
5 | Tie bar (Q235B) | SHS100×100×5.0 |
6 | Horizontal/Column brace (Q235B) | Ø16 |
7 | Steel stairs | [250#、[200#、[160# channel steel, 4mm checkered plate] |
8 | Angle brace (Q235B) | L50×6.0 |
9 | Roof purlin (Q355B) | C250×75×20×2.0 |
10 | Wall purlin (Q355B) | C250×75×20×2.0 |
11 | Connecting plate (Q235B) | 6mm–16mm |
3. Enclosure Part
No. | Item | Specification |
1 | Roof plate | 0.6mm thick, type 840 steel sheet |
2 | Exterior wall | 0.6mm thick, type 900 steel sheet |
3 | Steel man door | 910×2010×2 |
4 | Stainless steel handrail | 1.1m high |
5 | Roof ventilator | 600×600 |
6 | Gutter | 2.0mm galvanized |
7 | Downpipe | Ø110 PVC |
8 | Trimming | 0.55mm thick steel plate |
9 | Hardware accessories | Nails, supports, structural glue, etc. |